The Matrikon OPC Server for Triconex provides high-speed read and write access to the Triconex Tricon and Trident. The server supports all available point types, full communication redundancy and fail-over when a connection goes down.
The server can communicate via the new TCM (Triconex Communications Module), and the NCM (Network Communications Module), with no DCOM issues.
|
The server supports all available point types, full communication redundancy and fail-over when a connection goes down |
The server can communicate via the new TCM (Triconex Communications Module), and the NCM (Network Communications Module), with no DCOM issues |
The MatrikonOPC Server for Triconex has the ability to read device SOEs and return them as OPC A&E messages |
It also has the ability to read Tristation SOE files for enhanced A&E messages |
Matrikon's OPC Server Advantage
- OPC Security
- Device Communication Redundancy
- Advanced tag pre-processing (calculation)
- Alarm and Events
- Maximum Interoperability
- Simulation Mode
- User Defined Tag names
Enhance your process control with the ONLY certified Triconex OPC Server for Honeywell Experion
Achieve seamless high-speed access, complete redundancy, and advanced A&E messaging—boost your system’s reliability and efficiency now!The OPC Server for Triconex provides high-speed read and write access to the Triconex Tricon and Trident. This OPC Server is the ONLY Triconex OPC Server certified for use on Honeywell Experion!
Key Features
Tag Browse Capable
Configurable Time-Out
Redundance
Configurable Time-Out
Redundance
Customer Benefits
Flexible Client Application Connectivity Options
Dedicated Device Connectivity
Tag Database and Browsing Options
Extensive Tag Management Options
Diagnostic and Logging Options
Certified Compliant and Interoperability Tested
Common User Experience
Configuration to Optimize for a Specific System
Full Featured OPC Test Client – OPC Explorer
Dedicated Device Connectivity
Tag Database and Browsing Options
Extensive Tag Management Options
Diagnostic and Logging Options
Certified Compliant and Interoperability Tested
Common User Experience
Configuration to Optimize for a Specific System
Full Featured OPC Test Client – OPC Explorer
OPC Specs Supported
OPC A&E (OPC Alarms and Events) 1.0
OPC A&E (OPC Alarms and Events) 1.01
OPC A&E (OPC Alarms and Events) 1.1
OPC DA (OPC Data Access) 1.0a
OPC DA (OPC Data Access) 2.0
OPC DA (OPC Data Access) 2.05a
OPC DA (OPC Data Access) 3.0
OPC A&E (OPC Alarms and Events) 1.01
OPC A&E (OPC Alarms and Events) 1.1
OPC DA (OPC Data Access) 1.0a
OPC DA (OPC Data Access) 2.0
OPC DA (OPC Data Access) 2.05a
OPC DA (OPC Data Access) 3.0
Supports the following
- Triconex Tricon and Trident
- Read and write access to all points
- Read access to SOE (Sequence of Events) data using the OPC Alarms and Events standard. The latest version enables users to display SOE data
- in configurable text format
- Fail-over capability enables the OPC Server to use both a Primary and Standby connection
- Read data from a Triconex controller using polled or exception modes
- Multiple (1 to 10) TCP/IP addresses for each controller node
- Direct import of Tristation configuration information (XML file format)