20240930-slb-turnwell-jv-card

Gas Processing

Engineering & Marketing International
Technology

Aveva

Industry

Oil and Gas

Client

ADNOC

Country

UAE

Goals

Secure one-way data flow using Data Diode technology

Configure PI OPC Interfaces with OWL RED OSTS OPC Servers

Maintain data integrity with accurate tag reconfiguration

Validate performance through Site Acceptance Testing

Challenges

Integrating PI OPC Interfaces with Data Diode for secure transmission

Ensuring reliable communication across security layers

Reconfiguring large tag sets without disrupting operations

Solutions

Configured DCOM for PI OPC Interfaces and OWL RED OSTS Servers

Modified PI interfaces for secure data push via Data Diode

Reconfigured PI Server tags to align with new data sources

Performed thorough testing and troubleshooting to confirm system stability

Results

Achieved secure, reliable one-way data flow to headquarters

Enhanced cybersecurity without impacting real-time data access

Seamless integration with minimal operational disruption

Delivered a validated, tested PI solution aligned with ADNOC requirements

ADNOC Gas Processing Data Diode & PI Implementation

In 2023, EMI was awarded a critical project for ADNOC Gas Processing in Abu Dhabi aimed at securing and optimizing data communication by implementing Data Diode technology alongside enhanced PI System integration. This project focused on securing data flow from Level 4 site OPC servers to headquarters through one-way Data Diode technology, ensuring robust cybersecurity while maintaining high availability of real-time process data.

EMI configured OSI PI OPC Interfaces to communicate effectively with OWL RED OSTS OPC Servers situated behind the Data Diode, reconfigured thousands of tags on the existing PI Server to maintain data integrity and conducted rigorous Site Acceptance Testing (SAT) to validate system performance. The challenge was to integrate PI OPC Interfaces with the Data Diode’s secure, one-way transmission capabilities without disrupting ongoing operations, while maintaining reliable communications despite the additional security layers. EMI’s solution involved meticulous configuration of DCOM settings, modification of PI interfaces to accommodate the Data Diode, and comprehensive testing and troubleshooting to ensure seamless data flow and system robustness. The project resulted in a secure and reliable data transmission system that enhanced ADNOC’s cybersecurity posture without compromising operational data availability.